WATERPROOF CHARTS & TABLES
All Of The
Charts & Tables Are Designed To Be Taken Underwater
& They Are Pliable So They May Be Folded Or Rolled Up As Needed.
All Table Material is White with Multi-color Print For Ease of
Reading!
Please Do Not
Leave Them Inside Of The Manuals Or Texts As They
Will Absorb Printer & Xerox Ink - Thank You!
|
|
The Constant PO2 tables and ALL tables assume ideal circumstances for the Closed-Circuit Rebreather Diver OR the Open Circuit Diver and the dive. Consider your physical condition as well as conditions of the dive, then adjust the tables according to your training and experience. Proper use of these tables reduces the risk of decompression sickness and oxygen toxicity, but no tool can completely eliminate those risks. |
The Following Tables are on 7" x 9" Waterproof Material: |
|
| CCR Pre-Dive Safety Drills Sheet - A "MUST HAVE" Pre-Dive Review for every Rebreather Diver to be used on EVERY dive. | C-3401 |
| Isobaric Counter Diffusion Table for use with manual M-2222 Technical Encyclopedia | C-3402 |
| CCR Rebreather Skills Sheets - Set of 2 Tables |
C-3400-1A C-3400-1B C-3400-2A C-3400-2B |
|
1.2 PO2 / Air Diluent Table - Air Dil NDL & Deco. This constant 1.2 ATA PO2 table offers no-stop required decompression limit schedules for sport depths using Air as diluent. They also include required-stop schedules for advanced divers. |
C-3101 C-3101B |
| 1.2 PO2 / 21/15 Diluent Table - Normoxic Trimix NDL & Deco. This constant 1.2 ATA PO2 table offers no-stop required decompression limit schedules for sport depths using 15% Helium content or greater Normoxic Trimix as diluent. They also include required-stop schedules for advanced divers. |
C-3102 C-3102B |
| 1.2 – 1.3 PO2 15/30 Diluent Table - 30% Helium Dil Deco w/Optional Repet - This constant PO2 table provides required-stop decompression schedules for depths of 130 fsw (39 msw) to 200 fsw (60 msw) using 30% Helium content Trimix diluent. Each schedule includes the total % CNS Oxygen exposure. They also offer a single repetitive dive schedule assuming a minimum TWO-hour surface interval. |
C-3103 C-3103B |
| 1.3 – 1.4 PO2 14/44 Diluent Table - 44% Helium Dil Deco w/Optional Repet - This constant PO2 table provides required-stop decompression schedules for depths of 170 fsw (51 msw) to 240 fsw (72 msw) using 44% Helium content Trimix diluent. Each schedule includes the total % CNS Oxygen exposure. They also offer a single repetitive dive schedule assuming a minimum TWO-hour surface interval. |
C-3104 C-3104B |
| 1.2 – 1.4 PO2 8/60 Diluent Table - 60% Helium Dil Deco - This constant PO2 table provides required-stop decompression schedules for depths of 250 fsw (75 msw) to 400 fsw (120 msw) using 60% Helium content Trimix diluent. Also includes the total % CNS Oxygen exposure for each schedule. |
C-3105 C-3105B |
| Nitrox EAD - MOD Imperial Table. This table allows you to determine the EAD for any Nitrox mixture from 24% to 40% in 2% increments, and 45% to 100% in 5% increments. They also include the MOD for PO2s from 1.30 ATA to 1.60 ATA in 0.5 ATA increments for each Nitrox mixture. This EAD/MOD table, in combination with ANY Air table, allows you to determine a dive schedule for ANY Nitrox mixture without additional calculations. |
C-3200 C-3200B |
| Nitrox EAD - MOD Metric Table. This is the Metric version of our popular Equivalent Air Depth Table C-3200. | C-3204 |
| OTU - CNS O2 Tracking Table. Oxygen exposure tracking is important in technical and rebreather diving. Use these tables to determine the Percent CNS O2 clock or Oxygen Toxicity Units (OTU) for any time exposure to PO2's from 0.60 ATA to 1.60 ATA in 0.05 ATA increments. Use the surface interval credit table to determine residual % CNS for surface intervals of :30, :60, :90, and 2 to 6 hours. Also included is a table to determine PO2's at depths of 10 fsw (3 msw) to 220 fsw (67 msw) in 10 fsw (3 msw) increments for Air, Nitrox and Oxygen. |
C-3201 C-3201B |
| Gas Management - SRF Table. It determines gas usage rate at PSIG, allowing the diver to establish personal CFM rate. The Turn Pressure for divers with different tank sizes and breathing rates can also be determined (Rule of Thirds). | C-3202 |
| IANTD Openwater Air Table. To be used with all programs except Basic Nitrox. Uses fsw (msw) - 30 feet (9 meters) per minute ascent rate. | C-3800 |
| NOAA Nitrox I Table. Uses fsw (msw ) - 30 feet (9 meters) per minute ascent rate. | C-3300 |
| NOAA Nitrox II Table. Uses fsw (msw) - 30 feet (9 meters) per minute ascent rate. | C-3301 |
| US Navy Air Table. To 190 fsw (58 msw). This table utilizes 30 feet (9 meters) per minute ascent rate. This table is for Air with Air as the deco gas. These tables are IANTD's format of the current US Navy schedules. Many divers always keep an Air NDL & Deco table at hand for those rare moments when the carefully prepared dive plan has undergone unplanned transformation. As a result, the US Navy Air NDL & Deco tables continue to be one of our most popular. |
C-3302 C-3302B |
| Standard
Accelerated Tables. Six fsw (msw)
Decompression tables with the shallowest stop at 15 fsw
(4.5 msw). Based on the Bühlmann Model, decompression
configured with Bottom Mix or EAN 75+ at 20 to 15 fsw (6
to 4.5 msw) stops utilize EAN 78. Many divers prefer the Bühlmann
algorithm to the US Navy's. However, the repetitive letter group
designations are not transferable to ANY other tables, including the US
Navy tables. Please
specify which mix you prefer when ordering: Air, EAN 26, EAN 28, EAN 30, EAN 32 OR EAN 34 |
C-3500 (Set of 6) C-3501 (air) C-3501B (air) C-3502 (26%) C-3503 (28%) C-3504 (30%) C-3505 (32%) C-3506 (34%) |
| Extended Run Time Tables. These four tables begin with a minimum 30 fsw (9 msw) decompression stop. The 30 - 20 - 15 FSW (9 - 6 - 4.5 MSW) stops utilize EAN 78. Please specify which mix you prefer when ordering: Air, EAN 25, EAN 29, EAN 31 or EAN 33 (31 and 33 are on the same table). | C-3600 (Set of 3) C-3602 (25%) C-3603 (29%) C-3604 (31 & 33%) |
| Helium Mix Guide. The EANx - He Table references mixing Helium with Air or EANx. It also allows END determinations and PO2s in both fsw (msw) on Hypoxic mixtures. | C-3700 |
|
Normoxic
Trimix Table. This new Table
features a deep decompression stop at 90 fsw (27 msw) on 20% O2
and 25 HE Bottom Mix, with EAN 70 for shallower stops.
|
C-3713 |
| IANTD Nitrox Diving & Decompression Tables. These eight tables are based on Bühlmann's ZHL-16 algorithm, and are designed to be used for the IANTD EANx Diver Program. | C-3810 (Set of 9) C-3800 & B (Air) C-3811 (26%) C-3812 (28%) C-3813 (30%) C-3814 (32%) C-3815 (34%) C-3816 (36%) C-3817 (38%) C-3818 (40%) C-3818B (40%) |
| Advanced
EANx Tables - Air thru 36% NDL & Deco w/Optional 50% Accelerated Deco. Eight fsw (msw)
decompression tables w/ the shallowest stop at 15 FSW
(4.5 MSW). Based on the new Bühlmann Model ZHL-16,
deco configured with Bottom Mix or EAN 50+ (EAN 38 or EAN
40 on regular Deco) up to 100% Oxygen at the last two stop depths.
Please specify which mix you prefer when ordering: Air, EAN 26, EAN 30, EAN 32, EAN 34, EAN 36, EAN 38, or EAN 40. |
C-3900 (Set of 7) C-3901 (air) C-3901B (air) C-3902 (26%) C-3903 (28%) C-3904 (30%) C-3905 (32%) C-3905B (32%) C-3906 (34%) C-3907 (36%) C-3907B (36%) |
|
Altitude
Air Diving & Decompression Tables. These three tables range from 1,000 to 9,000 feet (305 to 2,745 meters) above sea level. |
C-3801
(1,000-3,000 ft) (305-915 ms) C-3802 C-3803 |
| 20/25 Normoxic Trimix Runtime Table w/Accelerated Deco. This table is for 20/25% Trimix (20% Oxygen) with 25% Helium or greater as the bottom gas. They also offer a single repetitive dive schedule assuming a minimum THREE-hour surface interval. This is the table to use for 21/35% Trimix. |
C-3703 C-3703B |
| 23/17-21 Normoxic Trimix Runtime Table w/Accelerated Deco. This Table is for Trimix Dives using 23% Oxygen with 17 to 21% Helium as the bottom gas. | C-3704 |
| 19/25-35 Normoxic Trimix Runtime Table w/Accelerated Deco. This Table is for Trimix Dives using 19% Oxygen and 25 to 35% Helium. | C-3705 |
| Trimix END Table. This is a Trimix Equivalent Narcosis Depth Table with calculations in both Imperial (fsw) and Metric (msw). | C-3706 |
| Trimix Variable Mix Run Time Tables. This set of five tables is based on the most recent version of Bühlmann's ZHL-16 algorithm as fsw (msw). Includes a 4 hour service interval repetitive table & a maximum of 3 gas switches with bottom mix, travel mix EAN 35 & EAN 75 for decompression. |
|
| Trimix Dive Decompression Run Time Tables. These new tables feature a deep decompression stop at 150 fsw (45 msw) to 170 fsw (51 msw) on the bottom mix, with EAN 36 and 75% for the shallower stops. These two tables are designed for diving to depths of 200 fsw (60 msw) to 310 fsw (93 msw) range. |
|
| 14% O2 and 50% HE | C-3710 |
| 16% O2 and 40% HE | C-3711 |
|
Stop Time Trimix 20% O2 / 25% He |
C-3713 |
|
Recreational Trimix 28/25 w/ 50%
Deco - 28/25% Trimix NDL & Deco |
C-3714 C-3714B |
|
Recreational Trimix 32/15 w/ 50%
Deco - 32/15% Trimix
NDL & Deco |
C-3715 C-3715B |
|
Recreational Trimix Set of 2 (C-3714 + C-3715) |
C-3716 |
|
Runtime Trimix 19/40 w/Accelerated Deco - This table is for 19/40% Trimix (19% Oxygen with 40% Helium or greater) as the bottom gas. They also offer a single repetitive dive schedule assuming a minimum TWO-hour surface interval. This is the table to use for 18/45% Trimix. |
C-3717 C-3717B |
|
Runtime Trimix 14/50 w/Accelerated Deco - This table is for 14/50% Trimix (14% Oxygen with 50% Helium or greater) as the bottom gas. They also offer a single repetitive dive schedule assuming a minimum TWO-hour surface interval. This is the table to use for 15/55% Trimix. |
C-3718 C-3718B |
| Runtime Trimix 12/60 w/Accelerated Deco - This table is for 12/60% Trimix (12% Oxygen with 60% Helium or greater) as the bottom gas. | C-3719 |
|
For Additional Questions
Please E-mail Us
Copyright © 1996 - 2010 IAND, Inc. DBA IANTD All rights reserved.
This page designed by IANTD TekHedz.